preloader
  • stuckeGROUP

Search Here

Advance Differential Protection Relay

Smart 1-Box Solution in Small Size

  • Stainless Steel Housing with Aluminum Front
  • Shallow depth - 90mm Depth with Terminals
  • 3× Status LEDs
  • Full Colour Touch screen Display
  • Remote Display (optional)
  • Customizable Menu Screens
  • Multilingual HMI
  • 8× Programmable LEDs
  • Pluggable Connections
  • Expandable with Additional I/O Boards
  • Two USBs Connection as Standard
  • RS485 with MODBUS RTU as standard
  • Control and interlocking of up to 8 Switching Elements
  • IEC: 61850, 60870-5-103, 104, Modbus RTU/TCP, Profibus DP, etc.
  • Up to 5 communication protocols can be used in the same time
  • High Speed GOOSE
  • 4 Processors for Ultimate Reliability and Speed
  • Self-Diagnostic
  • Almost all protection functions in standard version
  • Four Independent Protection Settings Groups
  • Independent and simultaneous protection for CT1 and CT2
  • Troubleshooting Pages
  • Event-driven architecture system with powerful extension capabilities

Advance Differential Protection and Control Relay with Advance Functionality and Flexibility

blog-thumbnail

SYMAP® Compact+ F4

Order code

SYMAP® Compact+ F4
Applications:
Cutout (WxH): (192x232)mm
Feeder Protection;
Overcurrent Protection;
Directional overcurrent;
Second and fifth harmonic blocking;
Generator Protection, Control and Monitoring; Differential protection Feeder protection, Control and Monitoring;
Transformer Protection;
Motor Protection; Generator+Transformer Protection;
Medium Voltage Distance Protection(optional);
Line differential protection;
Bay control;
Medium Voltage Soft Starters;
Radial and Looped distribution;
Dynamic Grid Support;
Housing dimensions (WxHxD): (210x250x87)mm
Dimensions front plate (WxHxD): (210x250x4)mm
Cutout (WxH): (192x232)mm
Front plate: design "Stucke"
LED indication:
3 status-LEDs (Trip: red/Alarm: red-flashing/System: red/green)
8 LED indications (parameterizable, red/green)
6 membrane keys (UP, DOWN, KEY, ACK, ON, OFF)
Graphical LC-Display/Touchscreen (320x240 pixel)
12V DC or 24V DC or 48V DC or 60 V DC
or 110V AC/DC; 220V DC;230V AC
1 x CT1 (3-phase:0-32 x In; secondary rated current);
and optional
1 x CT2 (3-phase:0-32 x In; secondary rated current);
1 x CT-GND1 (1-phase: secondary rated current)
1 x CT-GND2 (1-phase: secondary rated current)
1 x PT1 (3-phase:meas. ranges: 0-200V AC and 0-1000V AC; parameterizable);
1 x PT2 (3-phase:meas. ranges: 0-200V AC and 0-1000V AC; parameterizable);
1 x PT3 (3-phase:meas. ranges: 0-200V AC and 0-1000V AC; parameterizable);
1 x PT-GND1 (1-phase:meas. ranges: 0-200V AC and 0-1000V AC; parameterizable)
18 pcs. (Un: 24/48/60/220V DC; 110V AC/DC; /230V AC: parameterizable; HW_v1-2.x only!)
Optional:
Additional 50 Binary Inputs (EBS)
12 binary Outputs (potential-free contacts)
Optional:
Additional 24 Binary Outputs (EBS)
For function “Disturbance recorder” the device is equipped with a volatile 20 MB RAM-memory for buffering the measuring data. That internal-memory can be divided in up to 10 individual memory sections (buffers for recorded data). As soon as a recording is complete, the recording is transferred to an internal-memory 2GB SD Card. Maximum time of one recording is 126,62 seconds in the internal memory. Approximately 400 records. Both Comtrade formats are supported.
1 x mini-USB, on the side of the housing (parameter setting) - standard
1 x CANBUS1+CANBUS2 (external communication) - optional
1 x RS422/RS485 Modbus RTU - standard
1 x USB interface (front plate; parameter setting) – standard
1 x Rear side Ethernet communication: 2 x RJ45 or 2 x FO, or 1 x RJ45 and 1 x FO or 1 x FO or 1 x Rj45 - optional
1 x RJ45 on the side of the housing (parameter setting, service port) and extended boards - optional
1 x MODBUS RTU - standard
IEC60870-5-103, optional
IEC60870-5-104, optional
IEC61850, optional
MODBUS TCP, optional
MODBUS RTU (second), optional
SNTP, optional
IRIG-B, optional
PTP, optional
Indirect Control: 5 switching devices;
Field interlocking: 8 switching devices
ANSI: (21),21FL, 24, 25, (25A) 27, 27Q, 27T, 27/59TN, 32, 32N/G; 37, 40, 46, 46BC, 47, 48, 49, 50BF, 50/51, 50/51G/N, 51LR, 51/46VR, 52, 55, 59, 59AV, 59N/G, 64REF, 66, 67, 67G/N/W, 74TC, 78, 79, 81, 81R, 81RAV, 86, (87), (87LD), 95i, CLD, CTS, PTS, DCVM, SGF, SOTF, TIG, YG